Contact Us

TEL : +86-512-88161587
E-mail: orando@kylinsz.com
Address: 10005 room, Zhongxiang Financial Building, Jiayuan Road, Xiangcheng District, Suzhou, China.

Hot Runner Controller For Temperature Control System With CE Certification

Hot Runner Controller For Temperature Control System With CE Certification

Hot runner temperature controller for injection molding machine Power input voltage:AC185V~245V, 50/60Hz Temperature Control Type:PID Control / PIDD Temperature Sensor Type:Thermocouple J, K Unit temperature:C or F

KT-300D Detailed Introduction

1)Panel Instruction:

300D 2 zones hot runner controller

2)Main Picture:

 

8

12

16

32

 

NOTE:hot runner controller include 4 meters control cable and power cable


3) Main Specifications

-Indoor use

-Power input voltage:AC 185-245V,50/60HZ,15A

-Load:15A for each zone,100W-3600W

-Output type:PHA,OCR

-Thermocouple wire type:J or K

-Temperature control range:50~550

-Temperature control type:FUZZY +PIDD artifical intelligence+ shift-phase control

-Temperature stability:+0.5%

-Temperature precision:0.1

-Temperature resolution:0.1

Internal measurement loop automatic temperature compensation

Soft start can eliminate mold leakage function because of the wet

F2,F3: 250V-15A (special fuse)     

F1 :250-1A

 

4) Main Functions:

1>Using FUZZY PIDD control technology, it can automatically adapt to any fever model without setting PID parameters, greatly improve the work efficiency.

2>It can choose automatic temperature linear compensation makes the temperature controller is more accuracy;

3> It can monitor the error of the temperature sensor

The controller can detect reverse and open of the temperature sensor . When the sensor problem is detected, the temperature controller can operates according to the error type and the mode of it .  It also can automatic identify the thermocouple and heater, if it has the wrong line, the controller will give an alarm.  protecting and avoiding the damage of the thermocouple ,

4>Controller internal ring reconnaissance

5> The monitor of the current of heater

6> The check of the heater open, the protection of the heater short, avoiding the damage of the control card and alarm.

7> To alarm for temperature deviation and prompt the alarm.

8> Manual power output mode

9> A key for standby, a key for switch on/off.

10> According to the indicating output of the comprehensive error information, its easily to find the failure reasons. --Display errors completely to help you find failure reasons easily.

 

5) Operation Video

 

Click the link:https://www.youtube.com/watch?v=ZWBMxy-oqgc

6) Alarm Message

Num.

Displays

Fault

Checklist

1. 

otC

Thermocouple open

Use digital multimeter to check if thermocouple line is open or connect well

2. 

StC

Thermocouple shorten

Check if thermocouple line be pressed

3. 

rtC

Thermocouple inverted

Connect thermocouple line again

4. 

btC

Heater line &  tc line swapped

Check if heater line & tc line swapped

5. 

otr

Heater open

Use digital multimeter to check if the heater is open or the fuse  is break

6. 

Str

heater shorten

Use digital multimeter to check if the heater is shorten

NOTE:Own R&D department,dont worry the after-sale services.

7)Default Set

 

Num.

Menu

Default Value

1

Thermocouple Type

J

2

Temperature Unit

°C

3

         Output Mode

PHA

4

H Alarm

30°C

5

L Alarm

-30°C

6

Soft time

4 minutes

7

        Standby temperature

100°C

8

Operating temperature

120°C

 

8)Connection mode and power supply diagram

 

9)Contact us

SUZHOU KYLIN ELECTRONIC TECHNOLOGY CO.,LTD.

Contact Person: Orando Lu

Mobile/WhatsApp/ Wechat :+86 18355553130

Website:www.astcontrols.com

Email:orando@kylinsz.com

 


Hot Tags: hot runner controller for temperature control system with ce certification, China, manufacturers, suppliers, buy, for sale
Inquiry