KT-300S 10 Zones Digital Hot Runner Temperature Controllers China Supplier Provide OEM Service

Product Description Features: 1. Integrated construction permits easy disassembly. 2. Adopt galvanized steel sheet. Light and handy. High capacity of anticorrosion and antirust. 3. The card size and electric interface can be compatible with other brands such as YUDO, Athena, DME, PCS, INCOE. 4....

As one of the leading manufacturers and suppliers of various hot runner accessories in China, we pay great attention to quality. Welcome to buy our quality ast brand 12 zones digital hot runner temperature controllers china supplier provide oem service for sale. We'll offer you competitive price and excellent service.

Product Description

Features:
1. Integrated construction permits easy disassembly.
2. Adopt galvanized steel sheet. Light and handy. High capacity of anticorrosion and antirust.
3. The card size and electric interface can be compatible with other brands such as YUDO, Athena, DME, PCS, INCOE.
4. Adopt gold-plated card slot and machine to pressure wielding. Make sure the signals are connected reliably between box and card.
5. The type of heavy load connections and wiring method can be custom-made.
6. Adopt cold pressing terminals between wires and heavy load connections to make sure the signals are connected reliably.
7. There are 2, 4, 6, 8, 10, 12, 24 zones for customers to select.


Specification
1. Supply Voltage: AC185V~245V, 50/60Hz
2. Temperature Control Type: PID Control/Manual
3. Temperature Sensor Type: Thermocouple J, K
4. Temperature Measurement Accuracy: 0.1℃
5. Temperature Control Accuracy: 0.1℃

6. Ambient Temperature 32°F to 131°F (0℃ to 55℃)
7. Relative Humidity Tolerance 10 to 95 % Non-Condensing
8. Shipping Temperature -40 °F to 158 °F (-40℃ to 70℃)
9. Power Requirement 115 to 240 Vac 50 or 60 Hz nominal

10. Control Output Type: Triac(PWM mode); Triac(SSR mode)
11. Temperature Measurement Range: 0~500 Centigrade(32~932 Fahrenheit)
12. Temperature Setting Range: 0~450Centigrade (32~842 Fahrenheit)
13. Output Load Capacity: 15A, 100W~3600W

NOTE:KT-300S Series is according to the international standard. Hot runner controller  is equipped with the all function.

Alarm Message

Fault Display Solutions
Thermocouple breakagetC oPEn
display tC alternately with oPEn
Test the thermocouple with ohmmeter
Thermocouple “pinched” tC SHrt
display tC alternately with SHrt
Find where the thermocouple is pinched
Thermocpuple invertedtC rEu
display tC alternately with rEu
Check the thermocouple
Thermocouple and heater swappedtC bAd
display tC alternately with bAd
Check the thermocoule and heater
Scr breakageScr bAd
display scr alternately with bAd
Test the Scr with ohmmeter
The voltage is errorHIGH voL
display HIGH alternately with voL
Check the the input voltage in cabinet
Heater breakageHEAt oPEn
display HEAt alternately with oPEn
Test the heater with ohmmeter
Heater “pinched” out SHrt
display out alternately with SHrt
Find where the heater is pinched
Fuse breakageF1-2 brk
display F1or2 alternately with brk
Replace the fuse F1 or F2